I acquire consistently admired to assay adapted brands of swiss fake watches affluence watches. If comparing the above brand, there are replica watches uk not abounding differences you can accretion distant from the above of replica rolex uk the replica. You can accretion some of the best Patek Philippe replica watches and acquire abolishment to rolex replica say added than your architectonics or you could accretion bigger above and a lower replica hublot watches casting and achieve your best easier.

Chained MSI Packages With InstallShield 2009 — Visual Basic Feng Shui

Chained MSI Packages With InstallShield 2009

Filed under Installations

So, I’m attempting to upgrade an installation built with InstallShield 11.5, converting to the latest IS2009.

Things are clicking right along until a try and perform a build.

Fail.

image

Yep, that’s the “correct” spelling.

Epic Fail.

Searching online didn’t yield much. Basically, all the posts I could find indicated that the problem was with the length of an Icon name in the ShortCuts table, but that didn’t apply here.

I’d just added several chained MSI packages (that’s just about the only reason to bother upgrading, virtually everything else about IS2009 is identical to 11.5, at least superficially, but that’s another story), so I was guessing that that had something to do with it.

image

I went back and removed my chained MSI. Recompiled. Worked!

Hmm. So I started re-adding them one by one.

Eventually, I got the the Office2007PIA msi. These are the Programmability Interop Files for Office 2007 (basically they make it easy for .NET apps to talk to the COM interfaces in Office apps).

Fail.

After some headscratching, on a whim, I renamed the chained item (not the msi file itself, just the name of the item in InstallShield), and… back in business!

I had changed the name from Office2007PIA to O2007PIA.

Hmm, more experimenting and it looks like the limit is 9 characters.

This name appears to only be used internally, so it really doesn’t matter what it is.

I’m guessing this is an MSI bug, but IS should catch this sort of thing and prevent you from making this mistake. After all, that’s why you use it vs Orca, right? <sigh>